Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the header-footer-elementor domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/rovisimgroup/public_html/wp-includes/functions.php on line 6121

Notice: Funcția _load_textdomain_just_in_time a fost apelată incorect. Încărcarea traducerii pentru domeniul manufacturer a fost declanșată prea devreme. De obicei, este un indicator pentru codul unui modul sau a unei teme care rulează prea devreme. Traducerile ar trebui să fie încărcate la acțiunea init sau mai târziu. Te rog vezi Depanare în WordPress pentru mai multe informații. (Acest mesaj a fost adăugat în versiunea 6.7.0.) in /home/rovisimgroup/public_html/wp-includes/functions.php on line 6121
Filter Resistors - Rovisim Group

Rovisim Group

Rezistoare de filtrare

Filter Resistors

Suntem partenerul dvs. pentru implementarea în procesul de producție și nu numai, a unor soluții noi, performante și fiabile. Cu ajutorul experienței noastre în domeniul automatizărilor industriale, vă sprijinim activ pentru creșterea productivității, a competitivității și diminuarea costurilor și a consumurilor.

Asiguram servicii de consultanta, proiectare, executie, programare, instalare si service, la cele mai inalte standarde, fiind acreditati ISO 9001.

De-a lungul timpului, ne-am diversificat activitatea, oferind produse si servicii de cea mai inalta calitate, la preturi cat mai competitive, clientilor nostri din tara si strainatate, din diferite ramuri industriale si nu numai.

Send Enquiry
SKU ROVISIM-55 Categories ,

HARMONIC FILTER, DISCHARGE AND DAMPING RESISTORS

The demand for higher power quality and better network efficiency has led to the increasing use of static VAR compensators (SVC’s) and mechanically switched capacitor damping networks (MSCDN’s) in high-voltage three phase distribution networks throughout the world.

Many of the major wind generation sites are situated in remote locations, efficiently moving the  energy from these generation sites to areas of high consumption requires the use of good transmission design, this includes the use of harmonic filters which combine a reactive component (reactors and capacitors) with a resistor to provide controllable reactive power.

Harmonic filters are designed to allow through currents at the specified frequencies and to divert unwanted harmonic currents into the resistor, where they are dissipated as heat in a safe, controlled and reliable way and so removed from the system.

Inductors and capacitors are selected and matched to achieve this over the range of operating frequencies, in almost all cases it is preferable that the resistor has a low inductance (relative to resistance)  so that the value of resistance remains constant and that the distribution of voltage through the resistor is linear and can be defined.

Discharge resistors are used as safety devices to reduce the risks of sudden, unexpected and dangerous discharges from capacitors and inductors which have become isolated from their networks.

Unlike damping and filter resistors where duties can be over extended periods of time, discharge resistors must be capable of withstanding high peak currents and absorbing large energies in very short periods of time, for this they must withstand the mechanical and magnetic forces of the inrush current, have enough active resistor material to absorb the energy and be able to cool rapidly for potentially repeated operations.

 

discharge resistors capable of withstanding high peak currents

Cressall offer a range of technologies to meet the unique demands of these applications combined with the knowledge developed over 30 years of working with some of the global leaders in power transmission and power quality management.

Low inductance expanded mesh resistor elements are used for easy matching with capacitors and inductors.

Filter resistors are also an essential component in HVDC converter stations, where they act as part of the harmonic filters used to dissipate unwanted harmonics produced by the solid-state converters.

Details

Consultanță

Gratuită

Email

info@rovisimgroup.ro, office@rovisimgroup.ro

Furnizor

Rovisim Group

Garanție

Standard Oferită de Producător

Telefon

0332 416 819, 0723 711 811

impulse testing pre-insertion resistor

Cressall Pre-Insertion Resistor being prepared for RIV (Radio Interference Voltage) and through impulse testing. The resistor passed the RIV test at 275kV and the through impulse tests at 475kV

 

maintenance free resistors for improved efficiency

600kW naturally cooled resistor assemblies being manufactured in the UK at Cressall. These resistors, which are virtually maintenance free, will be supplied as part of a new series of compensation project being installed in the UK. The project is designed to improve the efficiency and power transfer capability of the transmission network.

 

Harmonic filters resistors are built to withstand extreme desert heat

Our harmonic filters resistors are built to withstand extremes of weather from desert heat to the worst Canadian winters.

Our harmonic filters resistors are built to withstand extremes of the worst Canadian winters.

Catalog ROVISIM

Introdu datele de contact pentru a descărca catalogul nostru